water-proof type armored thermocouple
http://www.ahdqjt.com time: 10/22/10 10:18application:
it is usually connected with display meter, recording meter and computer, ect, to directly measure temperature of liquid, vapor, gas and solid surface ranging from 0℃-1300℃ with explosives such as hydrocarbon on production spot.
operation theory:
the thermocouple is made of different materials. the temperature difference between measuring end and reference can result in thermoelectric potential. then the display meter indicates the corresponding temperature to the thermoelectric potential.
features:
- with quick response, reducing dynamic error
- optional installation methods
- wide measuring range
- high mechanical strength, good press-resistant performance
main technical parameters:
executive standard: iec584 gb/t18404-2001
meters