special thermocouple (thermal resistance)
http://www.ahdqjt.com time: 10/22/10 09:28application
we design special structure for different occasion to directly
measure the temperature of liquid, vapor, gas or solid surface
ranging from -200 to 1600 .
operation theory
thermocouple electrodes are made of two different
materials. temperature difference between measuring end and
reference end results in pyroelectric potential, then display meter
indicates the corresponding temperature to the pyroelectric
potential.
it is based on that material temperature change results in
change of its resistance. when resistance value changes, the
working instrument will display relevant temperature.
main technical parameters
executive standard
iec584
iec751
jb/t5582-1991
nominal pressure
it generally refers to sustainable static pressure on protection
tube from outside without breakage. it concerns not only material,
diameter, wall thickness of protection tube, but structure and
mounting way of the tube, flow speed and category of tested
media as well.
insulation resistance at normal temperature
the insulation resistance between electrode and protection
tube of the thermocouple shall be no less than 1000mw.m under
condition that evironment temperature is 20 15 , relative
humidity is no more than 80%, and test voltage is d.c.500
50v.
the insulation resistance between electrode and protection
tube of thermal resistance shall be no less than 100m under
condition that evironment temperature is 15 35 , relative
humidity is no more than 80%, and testing voltage is d.c.10~100v.
meters
尊龙登录 copyright © 2009-2011 anhui electric group shares co., ltd.