electromagnetic flow meter
http://www.ahdqjt.com time: 11/04/10 09:23
electromagnetic flow meter pother industries. without the effects of viscosity, temperature, pressure, density, it may determine the conductivity of the fluid. |
sensor |
||||
model |
dm43 |
dm47 |
dm41 |
dm48 |
ex-design |
no |
exd[ia]iamiict5 |
no |
exd[ia]iamiict5 |
size |
dn3-dn2000 |
|||
pressure class |
standard: 0.6-4.0 (divide according to calibre) |
|||
flange material |
carbon steel, stainless steel |
|||
liner |
rubber, ptfe, pfa and so on. |
|||
electrode material |
316,316l, hb, hc, titanium, tantalum, platinum-iridium, etc |
|||
grounding electrode (ring) material |
316,316l, hb, hc, titanium, tantalum, platinum-iridium, etc. |
|||
conductivity |
>= 5μs/cm |
|||
fluid temperature |
-40℃ ~+180℃ ( ptfe lining ), -25℃ ~+65℃ ( rubber lining ) |
|||
protection class |
ip67,ip68 |
|||
converters |
||||
supply power |
24vdc or 220vac |
|||
signal output |
electric current 4-20ma, frequency output,pulse output |
|||
power consumption |
<=10w (ac power supply;<=6w (dc power supply) |
|||
status display |
lcd,instant and accumulation |
|||
ambient condition |
ambient temperature: -20℃~60℃; relative humidity: 5%~90% |
|||
accuracy |
+(-)0.5% rate ( standard), +(-)0.2% rate (high accuracy ) |
|||
repeatability |
+(-)0.2% rate |
|||
measuring range |
recommended range of use:0.5m/s~10m/s continuous adjustable maximum range of use:0.01m/s~15m/s continuous adjustable |
|||
excitation |
frequency excitation 6.25,12.5,15,25,30hz |
|||
communication |
hart communication (option), rs485 communication (option) or field bus |
|||
protection class |
ip67orip68 |
ip67orip68 |
||
ex-design |
no |
exd[ia]iamiict5 |
no |
exd[ia]iamiict5 |
cable connection |
m20×1.5or1/2 〃 npt |
|||
housing |
cast aluminum |
meters