http://www.ahdqjt.com time: 11/05/10 14:32it is used for the circuit insensitive to interference of ac rated voltage 250v or lower for ships, offshore platform and other building over water.
executive standard: gb9332-88
type, description and installation requirements
type |
description |
installation requirements |
ckvv/da |
control cable with pvc insulation and sheath for ship |
|
ckvv80/da |
control cable with pvc insulation and sheath, bare copper wire braiding and armoring for ship |
|
ckvv82/da |
control cable with pvc insulation and sheath, copper wire braiding and armoring for ship |
|
ckvv90/da |
control cable with pvc insulation and inner sheath, bare steel wire braiding and armoring for ship |
|
ckvv92/da |
control cable with pvc insulation and inner sheath, pvc outer sheath, steel wire braiding and armoring for ship |
|
ckjv/da |
control cable with xlpe insulation and pvc sheath for ship |
|
ckjv80/da |
control cable with xlpe insulation and sheath, bare copper wire braiding and armoring for ship |
|
ckjv82/da |
control cable with xlpe insulation and pvc sheath, copper wire braiding and armoring for ship |
|
ckjv90/da |
control cable with xlpe insulation and pvc inner sheath, bare steel wire braiding and armoring ship. |
|
ckjv92/da |
control cable with xlpe insulation and pvc inner sheath, pvc outer sheath, steel wire braiding and armoring for ship |
technical requirements:
- cable should bear voltage test of av 1500v or dc 3600v for 5min
- vertical burning test performance for single piece shall meet the requirement of gb2951.19 standard
- insulated resistance constant is no less than 36.7mω.km at 20℃ for ckv series cable and 3670 mω.km at 20℃ for ckj series cable.